Short answer: Multiply your steam shower's length x width x height in feet to get cubic feet. Go one size up for every foot of ceiling over 8 feet, and for stone or porcelain walls. Then pick the generator from the chart below. Never go over the size's maximum room rating.
Measure the inside of the enclosure in feet. Multiply length x width x height. Always round your measurements up, as SteamSpa's spec sheets direct.
Example: a 4 ft x 3 ft shower with an 8 ft ceiling is 4 x 3 x 8 = 96 cubic feet.
The middle column is what SteamSpa's online sizing tool recommends for each room size. The right column is the most room each size can handle, from SteamSpa's spec sheets. Do not go over it.
| Your room (cu ft) | Recommended generator | Maximum room rating |
|---|---|---|
| Up to 63 | 4.5 kW | 90 cu ft |
| 64 to 83 | 6 kW | 150 cu ft |
| 84 to 104 | 7.5 kW | 225 cu ft |
| 105 to 140 | 9 kW | 300 cu ft |
| 141 to 168 | 10.5 kW | 400 cu ft |
| 169 and up | 12 kW | 450 cu ft |
Need more than 12 kW? The Black Series packages in our SteamSpa steam generator packages go up to 24 kW, but SteamSpa doesn't publish room ratings for those sizes. Send us your measurements before you order.
A 5 ft x 4 ft shower with an 8 ft ceiling:
Same idea with a taller ceiling: a 4 ft x 3 ft shower with a 9 ft ceiling is 108 cubic feet, which matches 9 kW. The ceiling is 1 ft over 8, so go one size up to 10.5 kW.
Every size needs its own dedicated circuit, per SteamSpa's spec sheets. SteamSpa's manual lists these for its 240V single-phase generators:
| Generator | Current | Power wire (AWG) |
|---|---|---|
| 4.5 kW | 19 A | 12 |
| 6 kW | 25 A | 10 |
| 7.5 kW | 32 A | 8 |
| 9 kW | 38 A | 8 |
| 10.5 kW | 44 A | 6 |
| 12 kW | 50 A | 6 |
The manual also calls for an independent circuit breaker, a power disconnect within sight of the generator, and grounding. A licensed electrician must do the wiring to local and national code. Check your panel has room for the circuit before you pick a size.
With an 8 ft ceiling, it's 96 cubic feet. A 4.5 kW unit is rated to 90 cubic feet, so it's too small. The 6 kW is the smallest size rated for this room (up to 150 cubic feet), and SteamSpa's sizing tool recommends 7.5 kW for it.
Yes. SteamSpa's manual says one size larger than its chart is safe and even recommended. Just make sure your electrical service can handle the larger size's current.
SteamSpa's own sources differ here. Its spec sheets size by volume only, while its online sizing tool asks about wall material and outside walls. For stone, porcelain or an outside wall, choosing one size up is the simple, safe choice.
From 19 A for 4.5 kW to 50 A for 12 kW, at 240V on a dedicated circuit. See the table above, and have a licensed electrician size the breaker and wire to code.
No. SteamSpa says it should not be installed in the steam room. Put it within 25 ft, indoors, in a dry spot with good ventilation that won't freeze. SteamSpa's diagram shows the space under a vanity as one possible spot.
Every SteamSpa steam generator package has a Wattage option. Indulgence, Royal and Oasis come in 4.5 to 12 kW, and the Black Series in 4.5 to 24 kW. For example, the SteamSpa OAT450GD Oasis Series package lets you pick any size from 4.5 to 12 kW. Browse all SteamSpa steam generators, or send us your measurements and we'll help you check the size.
Related guides: steam generator packages compared and steam shower vs. traditional shower.
Sources: SteamSpa spec sheets for the 4.5 to 12 kW generators (maximum room ratings, sizing rule, water lines, dedicated circuit); SteamSpa Installation & User Guide (electrical table, location rules, sizing chart); SteamSpa's online sizing tool; our live listings, checked November 5, 2026. Always check the current listing and spec sheet before you order.